Start-Up Flush
Open lower front door to access filter assembly, turn the water on
at the at the water connection, this brings water to the ball valve.
Disconnect the tube from the 2nd stage carbon filter (circle in figure
below) and place a cup or pan right underneath the hole to catch water.
Open ball valve inside the cooler 1/4-turn (handle in line with tube is “on”
and let water flow through filters into the bucket or pan to push out air and
carbon fines. When water runs clear, turn off ball valve and re-connect the
tube to the filter.
Turn on the water to the filter system by opening the ball valve inside the
cooler 1/4-turn (handle in line with tube is “on”). Check all connections to
assure there are no leaks.
Figure. 6 Filter configuration model “F” with cooler door opened